HomeWall SystemEngineeringProd. SystemsCompanyContact Us
Wall System
  Retaining + Screen Walls
  Various Types
  Corners + Curves
  Surface Designs

  Various Types

CRECAST steel forms can be adjusted to produce wall components of varying size and shape. The standard L-shape, designed for retaining applications with backfill (Fig. Ia), can be enhanced with a second spur of fixed dimensions (Fig. Ib). This will decrease the total lenght of the wall base and also meet the requirements for further loading scenarios of retaining applications. Figure IIb. shows the screen wall design with a tongue+groove added to the sides of the wall.


   

Fig. Ia                                            Fig. Ib                                            Fig. II




CRECAST walls are manufactured in two different steel forms:

11FT Steel Form

Wall Height:       2' - 11' (in grids of 1')
Base Length:     1'4'' - 6'4''
Thickness:         7'' / 10''
Prod. Capacity: 44ft² / cast

RETAINING WALL
(with or without spur)
SCREEN WALL
Wall
Height
Effect.
Length
sft /
unit
Base*
Thickness*
Wall/Base
Weight
(lbs)
lbs/
sft
Base*
Thickness*
Wall/Base
Weight
(lbs)
lbs/
sft.
2' 4' 8 1' 4" 7" 975 122 1' 4" 7" 975 122
3' 4' 12 2' 7" 1543 129 1' 4" 7" 1325 110
4' 4' 16 2' 4" 7" 2002 125 1' 8" 7" 1784 111
5' 4' 20 3' 7" 2570 129 2' 7" 2242 112
6' 4' 24 3' 8" 7" 3138 131 2' 7" 2592 108
7' 4' 28 4' 4" 7" 3706 132 2' 4" 7" 3051 109
8' 4' 32 5' 10" 5976 187 3' 7" 3619 113
9' 4' 36 5' 6" 10" 6632 184 3' 8" 7" 4187 116
10' 4' 40 6' 10" 7443 186 4' 7" 4646 116
11' 4' 44 6' 4" 10" 8099 184 4' 4" 7" 5105 116

click wall height for additional info

* Assumed, standard parameters. Thickness and Base Length may vary, depending on site-specific conditions.



16FT Steel Form

Wall Height:       8' - 16' (in grids of 1')
Base Length:     5' - 8'4''
Thickness:         10'' / 12'' / 14''
Prod. Capacity: 64ft² / cast

RETAINING WALL
(with or without spur)
SCREEN WALL
Wall
Height
Effect.
Length
sft /
unit
Base*
Thickness*
Wall/Base
Weight
(lbs)
lbs /
sft
Base*
Thickness*
Wall/Base
Weight
(lbs)
lbs/
sft.
8' 4' 32 5' 10" 5976 187 3' 10" 5040 157
9' 4' 36 5' 4" 10" 6632 184 3' 8" 10" 5852 163
10' 4' 40 6' 10" 7443 186 4' 10" 6507 163
11' 4' 44 6' 4" 10" 8099 184 4' 4" 10" 7163 163
12' 4' 48 6' 8" 12" 10406 217 4' 8" 10" 7818 163
13' 4' 52 7' 12" 11192 215 5' 10" 8473 163
14' 4' 56 7' 8" 14" 14079 251 5' 4" 10" 9129 163
15' 4' 60 8' 14" 14997 250 4' 8" 10" 9784 163
16' 4' 64 8' 4" 14" 15915 249 6' 10" 10440 163

click wall height for additional info

* Assumed, standard parameters. Thickness and Base Length may vary, depending on site-specific conditions.

Note: These typical details are preliminary and conceptual in nature. Site specific design must always be provided by a licensed Professional Engineer, who is familiar with the actual site conditions, materials and practices.



Contact Us
  CreCast Inc
  Toll free: 1-866-339-8527
  Phone: +49 5429-9444-11
  Fax: +49 5429-9444-33
  E-mail: Click here
© 2006 Crecast, Inc. - All Rights reserved